2018-06-27, 04:00 PM | #1 |
دكتور رابد
تاريخ التسجيل: Jun 2016
المشاركات: 15,175
معدل تقييم المستوى: 24 |
Zuken E³.series 2017 version.18.32 Update
Zuken E³.series 2017 version 18.32 Update | 291.0 mb Designer-16686 Connection lines are merged although they have different variant/option definitions Designer-26181 Unexpected behavior of inheritance and display when using fields in connection with options Designer-30098 Locked options which lock the complete tree Designer-30401 When comparing two E3.series projects, the text is not displayed with the font size given in the parameter 'FontSize' (ini-file) after text changes Designer-30779 COM: Method "prj.DeleteMultiuser" doesn't delete the project when an opened project has been closed with "prj.Close" before Designer-30910 At split/merge of connector pins in formboard the following message appears 'No formboard symbols defined for this connector. Please choose a symbol.' Designer-31119 Text types for displaying assigned variants/options and the tooltip display the text "Symbol options" instead of "Symbol variants" when using symbols with Boolean operators Designer-31330 Unnecessary messages at auto routing of connectors when some pins have been changed manually before Designer-31374 The database editor (DBE) uses additional licenses when starting Designer-31409 Objects assigned to not existing options are displayed in version 2014A but not in 2017 Designer-31443 Since validation errors may appear 'E - ITEM_TYP/nnn (GID)::...' after starting E3 (outside the domain 'eas-local') Designer-31464 Export to TIFF Format creates a black area outside the sheet format when a certain size is given Designer-31492 The text type "Conductor in Connection" at connected symbols is not saved in MU project after change of wire name by TriggeredScript Designer-31497 The COM method "Dev.SetOptionExpressionsWithFlags" doesn´t work correctly when called internally Designer-31500 Update in project of subcircuit in project may delete overlapping connections Designer-31572 Incorrect display of shield symbols after DGN Import Designer-31583 View definition for connector symbols in DBE - Selection list shows same names in different languages Designer-31593 The COM method "Graph.SetArrows" works only with lines Designer-31595 When placing a symbol the higher level assignment and location is not taken from the sheet despite the active setting Designer-31596 Inactive commands in context menu of connector device Designer-31597 When importing a sub-circuit wires are removed from overbraid Designer-31598 Trigger 'AfterOpenProject' is executed before 'AfterLaunchE3' Designer-31609 The COM method "GetSignalname" from the Connectioninterface doesn't work for connections with wires Designer-31615 Checkbox "Assign wire names automatically" is not set after reload settings from a template file (E3T) Designer-31633 COM: Delete of SignalClassInterface returns 0 (successful) in case of error Designer-31636 After having saved a project with "Save current configuration without variants / options", conductor namings disappear when deleting and placing a symbol again Designer-31639 GraphicalCompare: Graphical comparison of two E3S files results in structure nodes hanging on faulty/unexpected locations/structure nodes Designer-31642 Paste of copied objects might take very long Designer-31644 Existing outer diameters for cable conductors are missing after editing in database Designer-31646 Connection with mating connector can't be generated due to message "Pin(s) already plugged in another view and it's not possible to create a connector in current view" Designer-31667 Using the command "Merge all non-colliding" automatically renames assemblies because of colliding assembly components Designer-31674 Dimension length is displayed incorrectly at unmeasured cable ducts Designer-31676 Structure in PDF is missing when the first folder in project has the same name as the project itself Designer-31681 Security query is missing in Database Editor when saving ("Please note! This structure is used by n other component(s)...") for components with the same structure, when normal views are changed Designer-31692 System my crash when clicking a pictogram on a symbol under certain circumstances Designer-31694 Physical length of a hose/tube is not displayed Designer-31730 The COM command "GetSignalname" from the Connectioninterface doesn't work for connections which are also placed on a Formboard Designer-31731 Poor quality at TIFF Export Designer-31733 After using 'Merge all non-colliding' shields are incorrectly assigned Designer-31734 Wires are saved to the project after 'Merge all non-colliding' although the setting 'Create unique names' (for wires) is checked Designer-31744 Performance problems might appear when moving objects on a sheet Designer-31746 The model characteristic selection list shows "" although a model without characteristic doesn't exist Designer-31762 W - chain\validate_this' messages are displayed when views with pin views are existing in project Designer-31806 Text for block file (E3B) at blocks is not displayed Designer-31847 No functionality of E3 when all objects are moved on a Panel sheet Designer-31854 Hidden text levels are displayed at transparent models in 3D Designer-31860 When values in the "description" column of the language database correspond to an already used "description", it will not be updated in existing projects Designer-31861 When generating a new connection between a connection (with assigned variant) and a pin of a default device, the connection loses its variant assignment Designer-31888 No ability to create new MU projects based on already existing MU projects Designer-32040 Red conductor arrow is displayed on a symbol although the conductor/wire is connected Designer-32042 E3 doesn't respond anymore at preview or when clicking an assembly within the database window with E3.schema (problem occurs only with schema license, not with cable) Designer-32045 Incorrect display of conductor logic lines in connection with shields About Zuken E³.series 2017. Zuken's E3.series is a Windows-based, scalable, easy-to-learn system for the design of wiring and control systems, hydraulics and pneumatics. Its object-oriented architecture provides an integrated and consistent design approach to help eliminate errors, improve quality and reduce design time. The latest release contains new and enhanced functionality that further increases productivity throughout all phases of engineering, from design to manufacture. New third party integrations extend the E3.series ecosystem of solutions. Enhancements in E3.series 2017 cover all main E3.series modules: E3.schematic, E3.cable, E3.panel, E3.formboard and E3.PLC Bridge. About Zuken. Zuken works globally with leading companies to optimize their electrical and electronic engineering design and related manufacturing processes through the provision of leading edge software and consulting services. Our unique combination of proven experience, technological expertise and agility creates best in class solutions. Our transparent working practices and belief in integrity in all aspects of business produces long lasting and successful customer partnerships. Product: Zuken E³.series Version: 2017 version 18.32 Update Only Supported Architectures: 32bit / 64bit Website Home Page : كود:
http://www.zuken.com System Requirements: PC Supported Operating Systems: Windows 7even and newer Software Prerequisites: Zuken E³.series 2017 or above Size: 291.0 mb Download link: كود:
Links are Interchangeable - No Password - Single Extraction
|
|
|
المواضيع المتشابهه | ||||
الموضوع | كاتب الموضوع | المنتدى | مشاركات | آخر مشاركة |
Zuken E3.series 2016 version 17.00 180309 | rollroy12 | مواضيع عامة | 0 | 2018-03-09 12:38 PM |
Zuken E3.series 2016 version 17.00 171205 | rollroy12 | مواضيع عامة | 0 | 2017-12-05 11:54 AM |
Zuken E3.series 2016 version 17.00 170808 | rollroy12 | مواضيع عامة | 0 | 2017-08-08 04:31 AM |
Zuken E3.series 2016 version 17.00 170617 | rollroy12 | مواضيع عامة | 0 | 2017-06-17 09:08 AM |
Zuken E3.series 2016 version 17.00 170601 | rollroy12 | مواضيع عامة | 0 | 2017-06-01 10:18 PM |